Battery Simulator: Voltage Sag and C-Rate

A lithium-ion battery is a rechargeable cell whose voltage depends on its state of charge and falls under load because of its internal resistance, V=Voc−IRiV = V_{oc} - I R_i. Its discharge current is expressed as a C-rate, C-rate=I/capacityC\text{-rate} = I / \text{capacity}, and the runtime is roughly capacity divided by current. A nominal cell is 3.6 to 3.7 V and 4.2 V when full.

  • Power off
  • Anode (graphite)
  • Separator
  • Cathode (metal oxide)
  • Lithium ions
  • Drag to rotate

Parameters

Cell chemistry, pack layout, internal resistance and capacity

Editable

Educational lithium-ion model with a typical open-circuit curve · Not a substitute for a cell datasheet

Live values

Off

0.0 s

Terminal voltage12.06V
Discharge current0A
C-rate0C
Power to the load0W
Loss in internal resistance0W
Efficiency0%
Estimated runtimePower off

Charts

Follow the voltage as the battery empties, and see how the internal resistance makes the voltage sag as the current rises.

Discharge curve

Terminal voltage and state of charge over time at this load, from the present charge down to the cut-off voltage.

Voltage and power against current

At the present charge the voltage falls linearly with current, and the output power peaks where load and internal resistance match.

See lithium ions cross the separator as the cell discharges, and how internal resistance, C-rate and state of charge shape the terminal voltage and runtime.

What is a lithium-ion battery?

A voltage source with a state of charge

A lithium-ion battery is a rechargeable cell whose voltage depends on its state of charge and falls under load because of its internal resistance, V=Voc−IRiV = V_{oc} - I R_i. Its discharge current is expressed as a C-rate, C-rate=I/capacityC\text{-rate} = I / \text{capacity}, and the runtime is roughly capacity divided by current. A nominal cell is 3.6 to 3.7 V and 4.2 V when full.

More about this simulator

Where it is used

Lithium-ion cells power phones, laptops, power tools, e-bikes and electric vehicles, because they store more energy per kilogram than lead-acid or nickel-metal-hydride chemistries. Packs connect cells in series for voltage and in parallel for capacity, and a battery management system monitors each cell. It prevents overcharge above 4.2 V and over-discharge below the cutoff, both of which damage the cell, and limits current to the rated discharge rate. Run a hands-on battery simulation: this free battery simulator works online in your browser, with live readouts beside the 3D model. Compare it with the capacitor simulator and the resistor simulator. The glossary defines C-rate.

Frequently asked questions

Why does battery voltage drop under load?
The internal resistance forms a voltage divider with the load, so the terminal voltage is V = E − I·R. The larger the current, the larger the drop. A cell reading 4.1 V at rest may show 3.7 V under heavy load, and the sag increases as the cell ages or gets cold.

What you will learn

  • Calculate the terminal voltage and load current from the open-circuit voltage, pack internal resistance and load resistance.
  • Explain how the open-circuit voltage follows the state of charge and why the terminal voltage sags further under heavier loads.
  • Relate the load current to the C-rate and compare the capacity-over-current runtime estimate with the simulated runtime to cut-off.
  • Compare load power, I²R loss and efficiency as the load resistance is reduced toward the pack's internal resistance.
  • Predict how adding cells in series changes the pack voltage, total internal resistance and cut-off voltage.
Model assumptions & references

Model assumptions and limitations

  • The open-circuit voltage comes from a fixed table for a 3.7 V NMC cell, from 3.0 V at 0% to 4.2 V at 100% state of charge, linearly interpolated and scaled in proportion to the chosen nominal cell voltage.
  • Each cell is an ideal voltage source with a constant series internal resistance; it does not change with state of charge, temperature, age or current, and no polarization, transient or relaxation effects are modelled.
  • The pack is a single string of identical cells in series (whole number, at least 1); pack voltage and resistance scale with the cell count. Parallel strings, cell imbalance and balancing are not modelled.
  • The load is a fixed resistance, so the current is I = E / (R_load + R_pack). Load values of 1 MΩ or more count as disconnected, and the pack then rests at its open-circuit voltage.
  • Discharge ends at a cut-off of 2.75/3.7 of the nominal voltage per cell (2.75 V for a 3.7 V cell). Runtime is found by stepping the state of charge down in 120 steps from its present value, using the mean current in each step.
  • Capacity in Ah is fixed: there is no rate-dependent capacity loss, self-discharge or ageing, so high currents shorten runtime only because the voltage drop reaches the cut-off sooner.
  • Only discharge into a resistor is simulated: no charging, no cell temperature (I²R loss is reported only as power) and no protection circuit limiting the current; C-rates above 2C are only flagged as a warning.

References

  • Linden's Handbook of Batteries — Thomas B. Reddy (ed.). Covers lithium-ion chemistry, discharge curves, capacity, C-rate and cut-off voltage.
  • Battery Management Systems, Volume I: Battery Modeling — Gregory L. Plett. Covers the equivalent-circuit model of state-of-charge-dependent open-circuit voltage plus series internal resistance that underlies this simulator, and its extensions.
  • A Generic Battery Model for the Dynamic Simulation of Hybrid Electric Vehicles — Olivier Tremblay, Louis-A. Dessaint, Abdel-Illah Dekkiche. Describes a more detailed dynamic battery model that combines a state-of-charge-dependent voltage with internal resistance.