Curvo Studio

Part 2 · Chapter 15

Battery C-rate and runtime: how to calculate them

C-rate is the discharge current expressed as a multiple of the battery's capacity: a 3000 mAh cell at 1C delivers 3 A and, ideally, lasts one hour; at 0.5C it delivers 1.5 A for two hours; at 2C it delivers 6 A for 30 minutes. Runtime in hours is about 1 divided by the C-rate.

What C-rate means

A battery's capacity is given in ampere-hours (Ah) or milliampere-hours. The C-rate relates a current to that capacity:

C-rate=Icapacity in Ah,I=C-rate×capacity\text{C-rate} = \frac{I}{\text{capacity in Ah}}, \qquad I = \text{C-rate} \times \text{capacity}

So 1C is the current that would empty the battery in one hour. See C-rate for the definition. Datasheets quote a maximum continuous C-rate for discharge and a recommended one for charging, and the same number applies to different cell sizes, which makes it a convenient unit.

Examples for a 3000 mAh cell

  • 0.1C: 0.3 A, ideal runtime 10 h
  • 0.5C: 1.5 A, ideal runtime 2 h
  • 1C: 3 A, ideal runtime 1 h
  • 2C: 6 A, ideal runtime 30 min
  • 5C: 15 A, ideal runtime 12 min

The ideal runtime is capacity divided by current. In practice the usable capacity falls as the C-rate rises, because of internal resistance and voltage sag, so a real battery at 2C lasts a bit less than 30 minutes.

Worked example: runtime for a 5 W load

A 3.7 V (nominal), 3000 mAh lithium-ion cell holds 3.7×3.0=11.1 Wh3.7 \times 3.0 = 11.1\,\mathrm{Wh}.

1. Load current: I=5/3.7=1.35 AI = 5 / 3.7 = 1.35\,\mathrm{A}. 2. C-rate: 1.35/3=0.45C1.35 / 3 = 0.45\mathrm{C}. 3. Ideal runtime: 11.1/5=2.22 h11.1 / 5 = 2.22\,\mathrm{h}, which is 2 h 13 min. 4. With about 90% of the capacity usable and a converter efficiency of 90%, the runtime becomes 2.22×0.9×0.9=1.8 h2.22 \times 0.9 \times 0.9 = 1.8\,\mathrm{h}, about 1 h 48 min.

The usable fraction depends on the cut-off voltage, temperature and age, so treat the result as an estimate.

Internal resistance and voltage sag

A real cell has internal resistance, so its terminal voltage falls as the load current rises: Vterminal=Vopen−I×RintV_{terminal} = V_{open} - I \times R_{int}.

For RintR_{int} = 50 mΩ:

  • At 1C (3 A) the drop is 3×0.05=0.15 V3 \times 0.05 = 0.15\,\mathrm{V} and the loss in the cell is I2R=9×0.05=0.45 WI^2 R = 9 \times 0.05 = 0.45\,\mathrm{W}.
  • At 2C (6 A) the drop is 0.3 V and the loss is 1.8 W, four times higher, because loss grows with I2I^2.

This loss heats the cell, and the sag brings the voltage to the cut-off sooner, which is why high C-rates cut the usable capacity. The state of charge at which the voltage reaches the cut-off therefore depends on the load.

Charging C-rate

The same unit is used for charging. A common recommendation for lithium-ion cells is up to 0.5C to 1C, which means about 1.5 A to 3 A for the 3000 mAh cell, followed by a constant-voltage phase in which the current tapers. The time to reach the end of the first phase is about 1/C-rate1/\text{C-rate} hours, so at 0.5C it is about 2 hours, with some extra time for the taper. Always follow the manufacturer's maximum charge rate, since fast charging ages the cell.

Try it in the battery simulator

Open the battery simulator. Change the state of charge, the internal resistance and the load, and watch the voltage sag, the discharge curve, the C-rate, the runtime and the efficiency.

  • Increase the load until the C-rate reads 1C and compare the runtime with one hour.
  • Double the internal resistance and see the sag and the loss grow.
  • Compare the runtime at 0.5C and 2C to see how much the usable capacity shrinks.

Sources and further reading

  • D. Linden and T. B. Reddy (eds.), "Handbook of Batteries", McGraw-Hill.
  • I. Buchmann, "Batteries in a Portable World", Cadex Electronics.
  • IEC 61960, "Secondary lithium cells and batteries for portable applications".

Try it in the simulator

Frequently asked questions

What does 1C mean for a battery?
1C is the current that would discharge the battery in one hour, numerically equal to its capacity in ampere-hours. For a 3000 mAh cell, 1C is 3 A.
How do I calculate battery runtime?
Divide the capacity by the load current: runtime in hours = capacity in Ah / current in A. Multiply by the usable fraction, typically 80–90%, for a realistic estimate.
Why is the real runtime shorter at a high C-rate?
The internal resistance causes more voltage sag and loss at high current, so the cell reaches its cut-off voltage earlier and delivers less of its rated capacity.
What C-rate can I charge a lithium-ion battery at?