Curvo Studio

Part 4 · Chapter 22

Induction motor torque–speed curve: starting, pull-out and rated torque

An induction motor's torque–speed curve plots shaft torque against rotor speed, from standstill (starting torque) up to a maximum (pull-out or breakdown torque) and down to zero at synchronous speed. The motor runs stably on the steep part of the curve just below synchronous speed, where torque is almost proportional to slip.

What the torque–speed curve shows

The horizontal axis is rotor speed, from 0 rpm (standstill) to the synchronous speed NsN_s of the rotating field. The vertical axis is the torque the motor develops at that speed. A load is added as a second curve, and the motor settles where the two curves cross, the operating point.

The curve is easiest to read as four landmarks, from left to right: the starting torque at standstill, the pull-out torque at the peak, the rated point on the steep part, and zero torque at synchronous speed. The rotating magnetic field sets NsN_s, and the speed axis is often replaced by slip s=(Ns−N)/Nss = (N_s - N)/N_s, which runs from 1 at standstill to 0 at synchronous speed. The guide on induction motor slip covers that definition in detail.

The four key points on the curve

  • Starting torque (locked rotor, s=1s = 1): the torque available at standstill. It must exceed the load torque or the motor never starts. See starting torque.
  • Pull-out torque (also called breakdown or maximum torque): the peak of the curve, at a slip of about 10–25% for a standard cage motor. Above this load the motor slows down and stalls. See pull-out torque.
  • Rated point: the nameplate torque and speed, a few percent below synchronous speed. This is where the motor spends its life.
  • Synchronous speed (s=0s = 0): torque is zero, because with no relative motion nothing is induced in the rotor.

For a standard cage motor the pull-out torque is typically 2 to 3 times rated torque and the starting torque is around 1.5 to 2.5 times, but the exact values depend on the rotor design.

The equations behind the curve

From the per-phase equivalent circuit, with the supply reduced to a Thévenin source VthV_{th}, RthR_{th}, XthX_{th} and the rotor referred to the stator (R2′R_2', X2′X_2'), the developed torque is

T=3ωs⋅Vth2 R2′/s(Rth+R2′/s)2+(Xth+X2′)2T = \frac{3}{\omega_s} \cdot \frac{V_{th}^2 \, R_2'/s}{(R_{th} + R_2'/s)^2 + (X_{th} + X_2')^2}

where ωs=2πNs/60\omega_s = 2\pi N_s / 60 is the synchronous speed in rad/s. Setting the derivative with respect to ss to zero gives the slip at maximum torque:

smax=R2′Rth2+(Xth+X2′)2s_{max} = \frac{R_2'}{\sqrt{R_{th}^2 + (X_{th} + X_2')^2}}

Two consequences follow. Torque scales with Vth2V_{th}^2, so the whole curve shrinks with the square of the voltage. And smaxs_{max} is proportional to rotor resistance, but the peak torque does not depend on it, which is why adding resistance in a wound-rotor motor slides the peak toward standstill without lowering it.

A quick estimate near the peak is Kloss's formula, T/Tmax=2/(s/smax+smax/s)T / T_{max} = 2 / (s/s_{max} + s_{max}/s), which ignores stator resistance.

Worked example: a 4 kW, four-pole motor

Take the default motor of the three-phase induction motor simulator: 4 kW, 400 V, four-pole, 50 Hz, nameplate speed 1440 rpm.

1. Synchronous speed: Ns=120×50/4=1500 rpmN_s = 120 \times 50 / 4 = 1500\,\mathrm{rpm}. 2. Rated slip: s=(1500−1440)/1500=4%s = (1500 - 1440)/1500 = 4\%. 3. Rated torque: T=P/ω=4000/(2π×1440/60)≈26.5 N⋅mT = P/\omega = 4000 / (2\pi \times 1440 / 60) \approx 26.5\,\mathrm{N\cdot m}. 4. In the simulator's equivalent-circuit model the breakdown torque is about 82 N·m, which is 82/26.5≈3.182 / 26.5 \approx 3.1 times rated, and the starting torque is about 55 N·m, about 2.1 times rated. The locked-rotor current is about 48 A against 8.2 A at rated load.

Check with Kloss's formula. At rated load T/Tmax=1/3.1=0.32T/T_{max} = 1/3.1 = 0.32, so s/smax+smax/s=6.2s/s_{max} + s_{max}/s = 6.2. Solving gives smax/s≈6.03s_{max}/s \approx 6.03, so smax≈0.24s_{max} \approx 0.24. At standstill the formula then gives Tstart/Tmax=2/(1/0.24+0.24)≈0.45T_{start}/T_{max} = 2 / (1/0.24 + 0.24) \approx 0.45, about 37 N·m. That is lower than the simulator's 55 N·m, because Kloss's formula is only an approximation and the simulator's circuit model includes the stator resistance and leakage reactances. Use the formula for a feel for the shape, not for design.

What moves the curve

  • Voltage: torque goes with the square of the voltage. At 80% voltage, the peak falls to 0.82=64%0.8^2 = 64\%, from about 82 N·m to about 52 N·m in the example above, and the starting torque falls from 55 N·m to about 35 N·m.
  • Frequency: at constant voltage, lowering the frequency raises the torque peak and the magnetizing current. A drive therefore lowers the voltage in proportion, which keeps the peak roughly constant and moves the curve to a lower NsN_s, the idea behind V/f control in a VFD.
  • Rotor resistance: more resistance in a wound rotor raises the starting torque and moves the peak toward standstill.
  • Rotor design: deep-bar and double-cage rotors change the shape of the left half of the curve, giving more starting torque with low slip at rated load, as described by the NEMA design letters and IEC design classes.

The load matters as much as the motor. A fan or pump load torque rises with the square of speed and crosses the motor curve low on the steep part, while a constant-torque load such as a conveyor needs the motor curve to stay above it all the way from standstill.

Try it in the induction motor simulator

Open the three-phase induction motor simulator, keep the default 4 kW motor and look at the Torque-speed curve chart: the Motor torque curve, the Load torque curve, the Operating point and the Breakdown torque.

  • Raise the Mechanical load and watch the operating point slide up the steep part of the curve.
  • Lower the Applied line voltage to 80% (320 V) and read the Breakdown torque again. It should fall to about 53 N·m.
  • Keep lowering the voltage at a high load until the motor is flagged Stalled.
  • Open the wound-rotor induction motor simulator and add External rotor resistance to see the starting torque rise.

Sources and further reading

  • S. J. Chapman, "Electric Machinery Fundamentals", chapter on induction motors (torque–speed characteristics and the equivalent circuit).
  • A. E. Fitzgerald, C. Kingsley and S. D. Umans, "Electric Machinery", chapter on induction machines.
  • IEC 60034-12, "Rotating electrical machines: Starting performance of single-speed three-phase cage induction motors".
  • IEEE Std 112, "Standard Test Procedure for Polyphase Induction Motors and Generators".

Try it in the simulator

Frequently asked questions

What is pull-out torque on an induction motor?
It is the maximum torque the motor can produce, at the peak of the torque–speed curve. If the load torque is above it, the motor slows down and stalls. A standard cage motor has a pull-out torque of roughly 2 to 3 times its rated torque.
Why does torque fall to zero at synchronous speed?
Torque comes from currents induced in the rotor, and those exist only when the rotor moves relative to the rotating field. At synchronous speed there is no relative motion, so no induced current and no torque.
How does voltage affect the torque–speed curve?
Torque is proportional to the square of the voltage, so the whole curve scales with V2V^2. At 80% voltage the available torque at every speed falls to about 64%.
Where on the curve does an induction motor run stably?
On the steep part between the pull-out point and synchronous speed, where an increase in load slows the rotor slightly and raises the torque. To the left of the peak, extra load lowers the torque and the motor stalls.