Part 4 · Chapter 23
Synchronous speed formula: Ns = 120 f / p
Synchronous speed is the speed of the stator's rotating magnetic field: Ns = 120 × f / p, with f the supply frequency in hertz, p the number of poles and Ns in rpm. A four-pole motor on 50 Hz has Ns = 1500 rpm; on 60 Hz it is 1800 rpm.
The formula and where it comes from
A three-phase stator winding with poles creates a rotating magnetic field. The field advances by one pole pair for every electrical cycle, so in one second it makes revolutions. Multiplying by 60 gives revolutions per minute:
With pole pairs the same equation reads . In rad/s, . The pole count is always even, because every north pole needs a south pole.
The speed depends only on frequency and pole count, not on voltage or load. That is why frequency is the way to control the speed of an AC motor, as described in the guide on VFD and V/f control.
Synchronous speed table for 50 Hz and 60 Hz
- 2 poles: 3000 rpm at 50 Hz, 3600 rpm at 60 Hz
- 4 poles: 1500 rpm at 50 Hz, 1800 rpm at 60 Hz
- 6 poles: 1000 rpm at 50 Hz, 1200 rpm at 60 Hz
- 8 poles: 750 rpm at 50 Hz, 900 rpm at 60 Hz
- 10 poles: 600 rpm at 50 Hz, 720 rpm at 60 Hz
An induction motor's nameplate speed is always a little below one of these values, so the table is the quickest way to find the pole count of a motor: a nameplate speed of 1470 rpm on a 50 Hz supply can only be a four-pole motor, because 1500 rpm is the nearest synchronous speed above it.
Worked examples
1. Six-pole motor on 50 Hz: . 2. A motor with a nameplate speed of 1470 rpm on 50 Hz: the nearest synchronous speed above is 1500 rpm (four poles), so the slip is , or 2%. 3. Rotor current frequency at that slip: . See rotor frequency. 4. Frequency needed for 1200 rpm from a four-pole stator: . 5. A four-pole motor taken from 50 Hz to 60 Hz: rises from 1500 to 1800 rpm, 20% faster, because speed follows frequency.
From synchronous speed to rotor speed
In an induction motor the rotor turns slower than the field. Rotor speed follows from slip:
At full load a 4 kW four-pole motor with 4% slip runs at . The full treatment of slip, including why it must exist, is in the guide on induction motor slip.
In a synchronous motor, such as a permanent-magnet synchronous motor, the rotor locks onto the field and turns at exactly at any load below pull-out, so slip is zero. That difference is the subject of the guide on induction vs synchronous motors.
Try it in the simulators
Open the three-phase induction motor simulator. Change the Supply frequency and the Pole count and watch the Synchronous speed readout follow . At 60 Hz and four poles it should read 1800 rpm.
Then open the wound-field synchronous motor simulator and compare: its rotor speed equals the synchronous speed whatever the load, until the pull-out torque is exceeded.
Sources and further reading
- S. J. Chapman, "Electric Machinery Fundamentals", sections on the rotating magnetic field and the speed of magnetic field rotation.
- A. E. Fitzgerald, C. Kingsley and S. D. Umans, "Electric Machinery", chapter on the fundamentals of AC machines.
- IEC 60034-1, "Rotating electrical machines: Rating and performance".
Try it in the simulator
Frequently asked questions
- What is the formula for synchronous speed?
- , where is the supply frequency in hertz, is the number of poles and is in rpm.
- What is the synchronous speed of a four-pole motor at 50 Hz and 60 Hz?
- rpm at 50 Hz and rpm at 60 Hz.
- Does synchronous speed depend on voltage or load?
- No. It depends only on the supply frequency and the number of poles. Load changes the rotor speed of an induction motor through slip, but not the synchronous speed.
- How do I find the number of poles from a nameplate speed?
- Find the synchronous speed just above the nameplate speed. A motor marked 1470 rpm on 50 Hz is close to 1500 rpm, so poles.